Biomedical Instrumentation Center

Uniformed Services University

BD FACSAria

BD FACSAria instrument

This state of the art high speed sorter is capable of detecting 15 fluorochromes simultaneously:

  • Two parameters plus SSC detected from the 488 nm Blue laser
  • Five parameters detected from the 561 nm Yellow-Green laser
  • Three parameters detected from the 633 nm Red laser
  • Five parameters detected from the 407 nm Violet laser

Two- and four-way bulk sorting devices for a variety of tube sizes

Automated Cell Deposition Unit (ACDU) for sorting to multiwell plates or microscope slides

Biosafety Hood and Aerosol Management Option for safe sorts of biohazardous samples

BD FACSAria
 

BD LSRII (Blue)

BD LSRII (Blue) instrument

  • This state of the art flow cytometry cell analyzer is capable of detecting 12 fluorochromes simultaneously:
    • Five wavelengths detected from the 488 nm argon laser:
    • Three wavelengths detected from the 407 nm Violet laser:
    • Three wavelengths detected from the 635 nm HeNe:
  • High Throughput Sampler (BD HTS) to process samples from 96- and 384-well plates.

BD LSRII (Blue)
Click image for larger view

BD LSRII (Orange)

BD LSRII (Orange) instrument

  • This state of the art flow cytometry cell analyzer is capable of detecting 14 fluorochromes simultaneously:
    • Five wavelengths detected from the 488 nm argon laser:
    • Three wavelengths detected from the 407 nm Violet laser:
    • Three wavelengths detected from the 635 nm HeNe:
    • Two wavelengths detected from the 355 nm UV laser:
    • Forward Scatter (FSC) PMT option complements small particle scatter detection:
  • High Throughput Sampler (BD HTS) to process samples from 96- and 384-well plates

BD LSRII (Orange)
Click image for larger view

 

Bio-Plex 200 System

  • Multi-analyte bioassay detection system capable of performing up to 100 assays simultaneously in a single microtiter plate well.
  • Multiplexed immunoassays, and other assays based on nucleic acids, enzyme function, and receptor-ligand interactions.

Bio-Plex 200 System

ImageStream Mark II Imaging flow cytometer

ImageStream Mark II Imaging flow cytometer is capable of producing detailed brightfield, darkfield, and fluorescence imagery for a wide range of quantitative, statistically robust image-based assays.

  • 488 nm 200 mW excitation laser
  • 642 nm 150 mW red excitation laser
  • 785 nm darkfield laser and brightfield LED lamp
  • 20X,40X, and 60X magnification
  • six high resolution imaging channels
ImageStream Mark II Imaging flow cytometer